Principle structure
Based on the thermal principle, a closed probe contains two resistors, one of which is heated as the detection resistor and the other is not heated as the reference resistor. When the medium flows, the heat on the heating resistor is taken away, the resistance value is changed, and the difference between the two resistors is used as the basis for judging the flow rate.
Characteristic
(1) Real-time monitoring of fluid condition in pipeline
(2) No moving parts, no maintenance and easy installation. One type is used for various pipe diameters.
(3) Provide switching output and display the fluid flow status in real time by 6 LEDs;
(4) The housing is a sturdy and well sealed aluminium alloy junction box.
(5) Low-power temperature sensor with high sensitivity and accuracy
Setting range: |
1…150cm/s(Water), 3…300cm/s(Oil), 20…2000cm/s(Air) |
Media temperature change: |
≤4℃/s |
Signal output: |
PNP, NPN, relay, Normally Open + Normally Closed (SPDT) |
Response time: |
1…13s,Typical values 2s |
Power supply: |
24V±20%DC 230V±15%AC |
Explosion-proof grade: |
Exd IIC T6 |
Power on: |
Maximum 400 mA (PNP or NPN type) Max. 4A (Relay Type) |
Electrical protection: |
Reverse phase, short circuit, Overload protection |
No-load current: |
MAX 80mA |
Media temperature: |
-20…80℃ |
Flow Indication: |
LED Row (6) |
Ambient temperature: |
-20…100℃ |
Setting method: |
Potentiometer Setting |
Wiring method: |
Internal lead of explosion-proof housing |
Pressure range: |
100bar |
Material: |
Housing: Low Copper Aluminum Alloy Joint: 304 stainless steel |
Protection class: |
IP67 |
Initialization time: | About 8s |
Fit the flow switch so that the medium flows at the flow rate that needs to be monitored and adjust the potentiometer so that the first green LED just lights up.The switch then releases when the flow rate is below the current value.To make the switching point smaller than the current flow rate, adjust the potentiometer to make the green LED brighter.
Interface mode: |
G14:G1/4 G12:G1/2 H: Outer Thread G: Inner Thread Other Threads Customizable S5:S50.5 Hygienic chuck |
Interface material: | 1:304 Stainless Steel 2:306 Stainless Steel 3. PTFE |
Power supply: | D: DC24V |
Output mode | P:PNP Output N:NPN Output C:Relay Output M4:4-20mA |
Switch point: | R: Normally open and normally closed (SPDT) |
Explosion-proof housing: | 4088 housing |